© 2009 Magnum Energy IncPage 40
Table A-1, MS-PAE Speci cations
Models MS4024PAE MS4448PAE MS3748PAEJ
Input battery voltage range 18.0 to 33.8 VDC 36.0 to 67.6 VDC 36.0 to 67.6 VDC
Absolute maximum DC input 50 VDC 68 VDC 68 VDC
Nominal AC output voltage
AC output voltage accuracy
Output frequency and accuracy 50 Hz ± 0.4Hz
Total Harmonic Distortion (THD)
Continuous power output 4000 VA (L-L) 4400 VA (L-L) 3700 VA (L-L)
(at 25° C with 12.5 VDC nominal)
(
max 81% out
p
ut imbalance from L-N
)(
max 81% out
p
ut imbalance from L-N
)(
max 81% out
p
ut imbalance from L-N
)
Continuous AC output current L-N: 27.0A/120VAC, L-L: 16.7A/240VAC L-N: 29.7A/120VAC, L-L: 18.3A/240VAC L-N: 25.0A/120VAC, L-L: 15.5A/240VAC
1 msec surge current (amps AC) L-N: 120, L-L 70 L-N: 120, L-L 70 L-N: 120, L-L 70
100 msec surge current (amps AC) L-N: 72, L-L 40 L-N: 75, L-L 40 L-N: 75, L-L 32
5 sec surge power (real watts) 5800 8500 6200
30 sec surge power (real watts) 5200 6000 6000
5 min surge power (real watts) 4800 5400 3600
30 min surge power (real watts) 4500 4800 3500
Maximum continuous input current 267 ADC 147 ADC 123 ADC
Inverter efficiency (peak) 93% 94% 91%
HBCO / HBCI (High Battery Cut Out / In) >33.8 VDC / 33.2 VDC >67.6 VDC / 66.4 VDC >67.6 VDC / 66.4 VDC
LBCO / LBCI (Low Battery Cut Out / In) 18.0 VDC (adjustable) / 25.0 VDC 36.0 VDC (adjustable) / 50.0 VDC 36.0 VDC (adjustable) / 50.0 VDC
AC Relay Transfer time (minimum)
Power Consumption - searching < 10 watts
Power Consumption - inverting (no load) 27 watts 25 watts 22 watts
Output Waveform
Continuous charger output at 25° C 105 ADC (@28.2VDC) 60 ADC (@56.4VDC) 55 ADC (@56.4VDC)
Input current for continuous rated output 15 AAC (at 120 VAC) per leg 17.5 AAC (at 120VAC) per leg 8 AAC (at 120VAC) per leg
Charger efficiency (peak)
AC input frequency range 40 to 60 Hz
AC input voltage range
Power factor
Transfer relay capability
Five stage charging capability
Battery temperature compensation
Internal cooling
Over-current protection
Over-temperature protection
Corrosion protection
Safety Listings NA
Warranty
Operating temperature
Nonoperating temperature
Operating humidity
Unit Dimensions (h x w x d)
Shipping Dimensions (h x w x d)
Mounting
Unit W eight
Shipping Weight
Max operating altitude
Specifications subject to change without notice
90%
120 / 240 VAC split phase
Pure Sine Wave
16 msecs
ETL listed to ANSI / UL STD 1741 and CSA STD C22.2 No. 107.1-01
60 Hz ± 0.04%
50 to 70 Hz
< 6 watts
15,000’ (4570 m)
60 lbs (27.2 kg)
2legsat30AACmaximumperleg
Bulk, Absorb, Float, Equalize (requires remote) and Battery Saver
0 to 95% RH non-condensing
2 years parts and labor
-20° C to +60°C (- F to 140° F)
-40° C to +70°C (-40° F to 158° F)
Physical Specifications
18.5” x 17.5” x12.5” (47 cm x 44.5 cm x 31.8 cm)
55 lbs (24.9 kg)
13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm)
Shelf or wall (vents not allowed to face downward unless ME-HOOD and ME-CB are installed)
Inverter Specifications
Charger Specifications
General Features and Capabilities
L-N: 60 to 140 VAC (120 VAC nominal)
L-L: 120 to 280 VAC (240 VAC nominal)
>0.95
<5%
L-N: 120 VAC ±5%, L-L: 240 VAC ±5% ( continuous power)
EnvironmentalSpecifications
Standard with included temp sensor (battery temp 0 to 50° C)
0 to 120 cfm variable speed drive using dual 92mm brushless DC fans
with two overlapping circuits
on transformer, MOSFETs, and ambient temperature
PCB’s conformal coated, powder coated chassis/top, and stainless steel fasteners
A.1 Speci cations